H7D2 Swimming pools
Part H7 Ancillary provisions and additional construction requirements · NCC 2019: NSW 3.10.1.0, 3.10.1
(1) Performance Requirement H7P1 is satisfied for a swimming pool with a depth of water more than 300 mm and which is associated with a Class 1 building, if it has safety barriers installed in accordance with—
AS 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and
AS 1926.2.
(2) Performance Requirement H7P2 is satisfied for a water recirculation system of a swimming pool with a depth of water more than 300 mm, if it complies with AS 1926.3.
Changed since NCC 2022. See NCC 2022 Volume Two H7D2, or show what changed.
(1) Performance RequirementH7P1 Requirement H7P1 is satisfied for a swimming pool with a depth of … building, if it has safety barriers installed in accordance with — AS 1926.1 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and AS 1926.2. (2) Performance RequirementH7P2 Requirement H7P2 is satisfied for a water recirculation system of a swimming … more than 300 mm, if it complies with AS 1926.3.
Removed words are struck through; added words are highlighted. Comparison of the text only.
State and territory variations all clauses side by side →
- NSW Replaced Delete clause H7D2 and insert NSW H7D2 as follows: (1) Performance Requirement NSW H7P1 is satisfied for a swimming pool with a…
- NT Replaced Delete subclause H7D2(1) and insert NT H7D2(1) as follows: (1) This sub-clause has deliberately been left blank. Restriction of…
- QLD Replaced Delete subclause H7D2(1) and insert QLD H7D2(1) as follows: (1) This sub-clause has deliberately been left blank. Restriction of…
- SA Added Insert SA subclause H7D2(3) in clause H7D2 as follows: (3) For the purpose of clause 6.1.1 of AS 1926.3, a skimmer box is an…
- TAS Replaced Delete subclause H7D2(2) and insert TAS H7D2(2) as follows: (2) Performance Requirement TAS H7P2 is satisfied for a water…
- WA Replaced Delete subclause H7D2(1) and insert WA H7D2(1) as follows: (1) Performance Requirement H7P1 is satisfied for a swimming pool…