Deemed-to-Satisfy Provision · NCC 2025 Volume One

B1D3 Determination of individual actions

Part B1 Structural provisions · NCC 2019: B1.2

Open B1D3 on NCC Online ↗

The magnitude of individual actions must be determined in accordance with the following:

Permanent actions:

the design or known dimensions of the building or structure; and

the unit weight of the construction; and

AS/NZS 1170.1; and

for a Class 7b building, a notional additional permanent roof load of not less than 0.15 kPa to support the addition of solar photovoltaic panels.

Imposed actions:

the known loads that will be imposed during the occupation or use of the building or structure; and

construction activity actions; and

AS/NZS 1170.1.

Wind, snow and ice and earthquake actions:

the applicable annual probability of design event for safety, determined by—

assigning the building or structure an Importance Level in accordance with Table B1D3a; and

determining the corresponding annual probability of exceedance in accordance with Table B1D3b; and

AS/NZS 1170.2; and

AS/NZS 1170.3 as appropriate; and

AS 1170.4 as appropriate; and

in cyclonic areas, metal roof cladding, its connections and immediate supporting members must comply with Specification 4; and

for the purposes of (v), cyclonic areas are those determined as being located in wind regions B2, C and D in accordance with AS/NZS 1170.2.

Actions not covered in (a), (b) and (c) above:

the nature of the action; and

the nature of the building or structure; and

the Importance Level of the building or structure determined in accordance with Table B1D3a; and

AS/NZS 1170.1.

For the purposes of (d) the actions include but are not limited to—

liquid pressure action; and

ground water action; and

rainwater action (including ponding action); and

earth pressure action; and

differential movement; and

time dependent effects (including creep and shrinkage); and

thermal effects; and

ground movement caused by—

swelling, shrinkage or freezing of the subsoil; and

landslip or subsidence; and

siteworks associated with the building or structure; and

construction activity actions.

Table B1D3a Importance Levels of buildings and structures

Importance level

Building Types

1

Buildings or structures presenting a low degree of hazard to life and other property in the case of failure.

2

Buildings or structures not included in Importance Level 1, 3 and 4.

3

Buildings or structures that are designed to contain a large number of people.

4

Buildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.

Table B1D3b Design events for safety — Annual probability of exceedance

Importance level

Non-cyclonic wind

Cyclonic wind (wind regions B2 and C)

Cyclonic wind (wind region D)

Snow

Earthquake

1

1:100

1:200

1:250

1:100

1:250

2

1:500

1:500

1:1000

1:150

1:500

3

1:1000

1:1000

1:2000

1:200

1:1000

4

1:2000

1:2000

1:5000

1:250

1:1500

Exemptions

B1D3(a)(iv) does not apply to a Class 7b building—

where 100% of the roof area is shaded for more than 70% of daylight hours; or

with a roof area of not more than 55m2; or

where more than 50% of the roof area is used as a terrace, carpark, roof garden, roof light or the like.

Tables

Changed since NCC 2022. See NCC 2022 Volume One B1D3, or show what changed.

The magnitude of individual actions must be determined in accordance … areas are those determined as being located in wind regions B2, C and D in accordance with AS/NZS 1170.2. Actions not … associated with hazardous facilities. Table B1D3b Design events for safety Importance level — Annual probability of exceedance for non-cyclonic Importance level Non-cyclonic wind Annual probability of exceedance for cyclonic Cyclonic wind Annual probability of exceedance for snow Annual probability of exceedance for earthquake (wind regions B2 and C) Cyclonic wind (wind region D) Snow Earthquake 1 1:100 1:200 1:250 1:100 1:250 2 1:500 1:500 1:1000 1:150 1:500 3 1:1000 1:1000 1:2000 1:200 1:1000 4 1:2000 1:2000 1:5000 1:250 1:1500 Notes B1D3(a)(iv) does not take effect until 1 October 2023. Exemptions B1D3(a)(iv) does not apply to a Class 7b building … a terrace, carpark, roof garden, roof light or the like.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet B1D3? A Performance Solution must meet the Performance Requirements it satisfies: B1P1, B1P2, B1P3. Start a Performance Solution →

Defined terms used