B1D3 Determination of individual actions
Part B1 Structural provisions · NCC 2019: B1.2
The magnitude of individual actions must be determined in accordance with the following:
Permanent actions:
the design or known dimensions of the building or structure; and
the unit weight of the construction; and
AS/NZS 1170.1; and
for a Class 7b building, a notional additional permanent roof load of not less than 0.15 kPa to support the addition of solar photovoltaic panels.
Imposed actions:
the known loads that will be imposed during the occupation or use of the building or structure; and
construction activity actions; and
AS/NZS 1170.1.
Wind, snow and ice and earthquake actions:
the applicable annual probability of design event for safety, determined by—
assigning the building or structure an Importance Level in accordance with Table B1D3a; and
determining the corresponding annual probability of exceedance in accordance with Table B1D3b; and
AS/NZS 1170.2; and
AS/NZS 1170.3 as appropriate; and
AS 1170.4 as appropriate; and
in cyclonic areas, metal roof cladding, its connections and immediate supporting members must comply with Specification 4; and
for the purposes of (v), cyclonic areas are those determined as being located in wind regions C and D in accordance with AS/NZS 1170.2.
Actions not covered in (a), (b) and (c) above:
the nature of the action; and
the nature of the building or structure; and
the Importance Level of the building or structure determined in accordance with Table B1D3a; and
AS/NZS 1170.1.
For the purposes of (d) the actions include but are not limited to—
liquid pressure action; and
ground water action; and
rainwater action (including ponding action); and
earth pressure action; and
differential movement; and
time dependent effects (including creep and shrinkage); and
thermal effects; and
ground movement caused by—
swelling, shrinkage or freezing of the subsoil; and
landslip or subsidence; and
siteworks associated with the building or structure; and
construction activity actions.
Table B1D3a Importance Levels of buildings and structures
Importance level
Building Types
1
Buildings or structures presenting a low degree of hazard to life and other property in the case of failure.
2
Buildings or structures not included in Importance Level 1, 3 and 4.
3
Buildings or structures that are designed to contain a large number of people.
4
Buildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.
Table B1D3b Design events for safety
Importance level
Annual probability of exceedance for non-cyclonic wind
Annual probability of exceedance for cyclonic wind
Annual probability of exceedance for snow
Annual probability of exceedance for earthquake
1
1:100
1:200
1:100
1:250
2
1:500
1:500
1:150
1:500
3
1:1000
1:1000
1:200
1:1000
4
1:2000
1:2000
1:250
1:1500
Notes
B1D3(a)(iv) does not take effect until 1 October 2023.
Exemptions
B1D3(a)(iv) does not apply to a Class 7b building—
where 100% of the roof area is shaded for more than 70% of daylight hours; or
with a roof area of not more than 55m2; or
where more than 50% of the roof area is used as a terrace, carpark, roof garden, roof light or the like.
Tables
Changed in NCC 2025. See NCC 2025 Volume One B1D3, or show what changed.
The magnitude of individual actions must be determined in accordance … areas are those determined as being located in wind regions B2, C and D in accordance with AS/NZS 1170.2. Actions not … associated with hazardous facilities. Table B1D3b Design events for safety Importance level — Annual probability of exceedance for non-cyclonic Importance level Non-cyclonic wind Annual probability of exceedance for cyclonic Cyclonic wind Annual probability of exceedance for snow Annual probability of exceedance for earthquake (wind regions B2 and C) Cyclonic wind (wind region D) Snow Earthquake 1 1:100 1:200 1:250 1:100 1:250 2 1:500 1:500 1:1000 1:150 1:500 3 1:1000 1:1000 1:2000 1:200 1:1000 4 1:2000 1:2000 1:5000 1:250 1:1500 Notes B1D3(a)(iv) does not take effect until 1 October 2023. Exemptions B1D3(a)(iv) does not apply to a Class 7b building … a terrace, carpark, roof garden, roof light or the like.