Deemed-to-Satisfy Provision · NCC 2025 Volume One

C4D17 Columns protected with lightweight construction to achieve an FRL

Part C4 Protection of openings · NCC 2019: C3.17

Open C4D17 on NCC Online ↗

A column protected by lightweight construction to achieve an FRL which passes through a building element that is required to have an FRL or a resistance to the incipient spread of fire, must be installed using a method and materials identical with a prototype assembly of the construction which has achieved the required FRL or resistance to the incipient spread of fire.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One C4D17.
Can't meet C4D17? A Performance Solution must meet the Performance Requirements it satisfies: C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8, C1P9. Start a Performance Solution →