Deemed-to-Satisfy Provision · NCC 2025 Volume One

D4D11 Swimming pools

Part D4 Access for people with a disability · NCC 2019: D3.10

Open D4D11 on NCC Online ↗

(1) Not less than 1 means of accessible water entry/exit in accordance with Specification 16 must be provided for each swimming pool required by D4D2 to be accessible.

(2) An accessible entry/exit must be by means of—

a fixed or movable ramp and an aquatic wheelchair; or

a zero depth entry and an aquatic wheelchair; or

a platform swimming pool lift and an aquatic wheelchair; or

a sling-style swimming pool lift.

(3) Where a swimming pool has a perimeter of more than 70 m, at least one accessible water entry/exit must be provided by a means specified in (2)(a), (b) or (c).

(4) Latching devices on gates and doors forming part of a swimming pool safety barrier need not comply with AS 1428.1.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One D4D11.
Can't meet D4D11? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P10, D1P9. Start a Performance Solution →