E3D7 Passenger lift types and their limitations
Part E3 Lift installations · NCC 2019: E3.6, Table E3.6a, Table E3.6b
(1) In an accessible building, every passenger lift must be one of the following lift types, subject to the limitations (if any) of each lift type:
There are no limitations on the use of electric passenger lifts, electrohydraulic passenger lifts or inclined lifts.
Stairway platform lifts must not—
be used to serve a space in a building accommodating more than 100 persons calculated according to D2D18; or
be used in a high traffic public use area such as a theatre, cinema, auditorium, transport interchange, shopping centre or the like; or
be used where it is possible to install another type of passenger lift; or
connect more than 2 storeys; or
where more than 1 stairway lift is installed, serve more than 2 consecutive storeys; or
when in the folded position, encroach on the minimum width of a stairway required by D2D8 to D2D11.
A low-rise platform lift must not travel more than 1000 mm.
A low-rise, low-speed constant pressure lift must not—
for an enclosed type, travel more than 4 m; or
for an unenclosed type, travel more than 2 m; or
be used in a high traffic public use areas in buildings such as a theatre, cinema, auditorium, transport interchange, shopping complex or the like.
(2) A passenger lift referred to in (1) must not rely on a constant pressure device for its operation if the lift car is fully enclosed.
Changed since NCC 2022. See NCC 2022 Volume One E3D7, or show what changed.
(1) In an accessible building, every passenger lift must be … theatre, cinema, auditorium, transport interchange, shopping complex or the like. A small-sized, low-speed automatic lift must not travel more than 12 m. (2) A passenger lift referred to in (1) must not … for its operation if the lift car is fully enclosed.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Clauses referred to
- D2D18 Number of persons accommodated
- D2D8 Width of exits and paths of travel to exits
- D2D11 Determination and measurement of exits and paths of travel to exits