Deemed-to-Satisfy Provision · NCC 2025 Volume One

F1D9 Damp-proofing of floors on the ground

Part F1 Water management

Open F1D9 on NCC Online ↗
Varied in SA. Check the variation for your state.

(1) If a floor of a room is laid on the ground or on fill, moisture from the ground must be prevented from reaching the upper surface of the floor and adjacent walls by the insertion of a vapour barrier in accordance with AS 2870.

(2) The requirements of (1) do not apply where—

weatherproofing is not required; or

the floor is the base of a stair, lift or similar shaft which is adequately drained by gravitation or mechanical means.

New in NCC 2025. No F1D9 in NCC 2022 Volume One; it may have moved or been renumbered.
Can't meet F1D9? A Performance Solution must meet the Performance Requirements it satisfies: F1P1. Start a Performance Solution →

State and territory variations all clauses side by side →