Deemed-to-Satisfy Provision · NCC 2025 Volume One

F6D3 Methods and extent of natural light

Part F6 Light and ventilation · NCC 2019: F4.2

Open F6D3 on NCC Online ↗

(1) Required natural light must be provided by—

windows, excluding roof lights, that—

have an aggregate light transmitting area measured exclusive of framing members, glazing bars or other obstructions of not less than 10% of the floor area of the room; and

are open to the sky or face a court or other space open to the sky or an open verandah, carport or the like; or

roof lights, that—

have an aggregate light transmitting area measured exclusive of framing members, glazing bars or other obstructions of not less than 3% of the floor area of the room; and

are open to the sky; or

a proportional combination of windows and roof lights required by (a) and (b).

(2) Except in a Class 9c aged care building, in a Class 2, 3 or 9 building or Class 4 part of a building, a required window that faces a boundary of an adjoining allotment or a wall of the same building or another building on the allotment must not be less than a horizontal distance from that boundary or wall that is the greater of—

generally — 1 m; and

in a patient care area or other room used for sleeping purposes in a Class 9a building — 3 m; and

50% of the square root of the exterior height of the wall in which the window is located, measured in metres from its sill.

(3) In a Class 9c aged care building, a required window must be transparent and located—

in an external wall with the window sill not more than 1 m above the floor level; and

where the window faces an adjoining allotment, another building or another wall of the same building, it must not be less than a horizontal distance of 3 m from the adjoining allotment, other building or wall.

(4) In a Class 9b early childhood centre, the sills of 50% of windows in children's rooms must be located not more than 500 mm above the floor level.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One F6D3.
Can't meet F6D3? A Performance Solution must meet the Performance Requirements it satisfies: F6P1, F6P2, F6P3, F6P4, F6P5. Start a Performance Solution →

Defined terms used