Deemed-to-Satisfy Provision · NCC 2025 Volume One

F7D5 Sound insulation rating of floors

Part F7 Sound transmission and insulation · NCC 2019: NT F5.4, F5.4

Open F7D5 on NCC Online ↗
Varied in NT. Check the variation for your state.

(1) A floor in a Class 2 or 3 building must have an Rw + Ctr (airborne) not less than 50 and an Ln,w (impact) not more than 62 if it separates—

sole-occupancy units; or

a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby or the like, or parts of a different classification.

(2) A floor in a Class 9c building separating sole-occupancy units must have an Rw not less than 45.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One F7D5.
Can't meet F7D5? A Performance Solution must meet the Performance Requirements it satisfies: F7P1, F7P2, F7P3, F7P4. Start a Performance Solution →