G2D3 Open fireplaces
Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues · NCC 2019: G2.3
An open fireplace, or solid-fuel burning appliance in which the fuel-burning compartment is not enclosed, must have—
a hearth constructed of stone, concrete, masonry or similar non-combustible material so that—
it extends not less than 300 mm beyond the front of the fireplace opening and not less than 150 mm beyond each side of that opening; and
it extends beyond the limits of the fireplace or appliance not less than 300 mm if the fireplace or appliance is free-standing from any wall of the room; and
its upper surface does not slope away from the grate or appliance; and
combustible material situated below or around the external edge of the hearth, but not below that part required to extend beyond the fireplace opening or the limits of the fireplace, is not less than 150 mm from the upper surface of the hearth; and
walls forming the sides and back of the fireplace up to not less than 300 mm above the underside of the arch or lintel which—
are constructed in 2 separate leaves of solid masonry with a total combined thickness not less than 180 mm, excluding any cavity; and
do not consist of concrete block masonry in the construction of the inner leaf; and
walls of the chimney above the level referred to in (b)—
constructed of masonry units with a net volume, excluding cored and similar holes, not less than 75% of their gross volume, measured on the overall rectangular shape of the units, and with an actual thickness of not less than 100 mm; and
lined internally to a thickness of not less than 12 mm with rendering consisting of 1 part cement, 3 parts lime, and 10 parts sand by volume, or other suitable material; and
suitable damp-proof courses or flashings to maintain weatherproofing.