Verification Method · NCC 2025 Volume One

G2V1 Combustion appliances

Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues · NCC 2019: GV2

Open G2V1 on NCC Online ↗

Compliance with G2P1(a) and G2P1(b) is verified when—

components used within an appliance and its installation are constructed from—

heat-resistant materials for maximum operating temperatures not less than 600℃, where the material complies with (c); or

heat-tolerant materials for maximum operating temperatures more than 150℃ and less than 600℃, where the material complies with (c); and

the building elements surrounding the appliance maintain their designed function and material properties inclusive of a full range of thermal movements when exposed to the heat effects of the appliance; and

a sample of the material is tested to the maximum operating temperature, specified in (a)(i) or (a)(ii) for a minimum of 96 hours; and

the tested sample, when allowed to cool, is free from—

visible cracks and fractures; and

visible indication of de-lamination; and

linear distortion in excess of the equivalent of 10 mm per metre, and

deterioration of the appearance of any surface finish, when compared to an unheated sample.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One G2V1.

Clauses referred to

Defined terms used