Deemed-to-Satisfy Provision · NCC 2025 Volume One

G4D3 External doors

Part G4 Construction in alpine areas · NCC 2019: G4.3

Open G4D3 on NCC Online ↗

External doors which may be subject to the build-up of snow must—

open inwards or slide; and

if inward opening, be marked “OPEN INWARDS” on the inside face of the door in letters not less than 75 mm high in a colour contrasting with that of the background; and

be constructed so that the threshold is not less than 900 mm above the adjoining surface; and

if it serves a corridor or stairway, be positioned in an alcove or recess with—

no horizontal dimensions of the alcove or recess less than twice the width of the door; and

the door positioned to open against a wall such that the distance from any part of its swing to the nearest point of entry of the stairway or corridor is not less than the width of the door.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One G4D3.
Can't meet G4D3? A Performance Solution must meet the Performance Requirements it satisfies: G4P1, G4P2, G4P3, G4P4. Start a Performance Solution →