NCC 2025 Volume One
Part G4 Construction in alpine areas
15 clauses · Open on NCC Online ↗
- G4O1 ObjectiveThe Objective of this Part is to safeguard occupants in alpine areas from illness or injury from an emergency while evacuating a building.…
- G4F1 Construction in alpine areasA building in an alpine area is to be provided with additional measures in view of the increased difficulties in fire-fighting and maintaining…
- G4P1 External doorwaysAn external doorway from a building in an alpine area must be installed so that opening the door is not obstructed by snow or ice. Applications G4P1…
- G4P2 Structures forming pathways in snow conditionsA building in an alpine area containing external trafficable structures forming part of the means of egress must be constructed so that those…
- G4P3 Control of falling ice and snowA building in an alpine area must be constructed so that snow or ice is not shed from the building onto the allotment, any adjoining allotment, road…
- G4P4 Fire safety systems in alpine areasA building in an alpine area must have a fire safety system installed to— facilitate fire-fighting operations; and alert occupants in the event of…
- G4D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements G4P1 to G4P4 are satisfied by complying with— G4D2 to G4D8; and for a…
- G4D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to any building constructed in an alpine area in addition to other Deemed-to-Satisfy Provisions…
- G4D3 External doorsExternal doors which may be subject to the build-up of snow must— open inwards or slide; and if inward opening, be marked “OPEN INWARDS” on the…
- G4D4 Emergency lightingIn a Class 2, 3, 5, 6, 7, 8 or 9 building or Class 4 part of a building, a system of emergency lighting must be installed in accordance with the…
- Table G4D5 Alternate stair riser and going dimensionsRiser (R) | Going (G) | Slope relationship (2R + G) Max | Min | Max | Min | Max | Min 150 | 115 | 375 | 355 | 675 | 605 Table Notes Dimensions are…
- G4D5 External trafficable structuresExternal stairways, ramps, access bridges or other trafficable structures serving the building must— have a floor surface that consists of expanded…
- G4D6 Clear space around buildingsA building must be so constructed that— if any part of an external wall is more than 3.6 m above the natural ground level — the distance of that…
- G4D7 Fire-fighting services and equipmentEvery Class 2, 3, 5, 6, 7, 8 or 9 building must have— a manually operated fire alarm system with call-points complying with AS 1670.1; and fire…
- G4D8 Fire ordersEvery Class 2, 3 or 9 building must display a notice clearly marked “FIRE ORDERS” in suitable locations near the main entrance and on each storey,…