New South Wales variation · NCC 2025 Volume One

NSW G1D2 Swimming pools

NSW Part G1 Minor structures and components · varies G1D2 Swimming pools

Open on NCC Online ↗

Delete clause G1D2 and insert NSW G1D2 as follows:

(1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict access to swimming pools, subject to—

out-of-ground pool walls and the walls of above ground pools, including inflatable pools, not being considered to be effective barriers; and

the reference in clause 2.3.1 of AS 1926.1 to ‘This clause shall not apply to boundary barriers.’ is replaced with ‘This clause shall apply to boundary barriers.’.

(2) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—

AS 1926.1 and AS 1926.2; or

if the swimming pool is a spa pool —

the requirements of (a); or

clause 9 of the Swimming Pools Regulation 2018.

(3) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.

Notes

The Swimming Pools Act 1992 and the Swimming Pools Regulation 2018, applicable to swimming pool with a depth of water of more than 300 mm, regulate the circumstances in which a barrier is required and prevail in the case of any inconsistency.

Changed since NCC 2022. See NCC 2022 Volume One NSW G1D2, or show what changed.

Delete clause G1D2 and insert NSW G1D2 as follows: (1) … and the reference in clause 2.3.1 of AS 1926.1 to a barrier within a property including a ‘This clause shall not apply to boundary barrier. barriers.’ is replaced with ‘This clause shall apply to boundary barriers.’. (2) A swimming pool with a depth of water more … is required and prevail in the case of any inconsistency.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause

Other states and territories