NCC 2025 Volume One
Part I3 Farm buildings and farm sheds
18 clauses · Open on NCC Online ↗
- I3D1 Application of Part SAThe Deemed-to-Satisfy Provisions of this Part apply to farm buildings and farm sheds. (2) The Deemed-to-Satisfy Provisions of this Part take…
- I3D2 Fire resistance and separation SAA farm shed need not comply with the provisions of Parts C2, C3 and C4, except for C2D12, if it is separated from any other building or allotment…
- I3D3 Provision for escape SAExcept for D2D3, D2D5 to D2D11, D2D14, D2D15(1), D2D18(c), D2D19 and D2D20, the Deemed-to-Satisfy Provisions of Part D2 do not apply to a farm shed.…
- I3D4 Construction of exits SAExcept for D3D14, D3D15, D3D17 to D3D21, D3D22 and D3D29, the Deemed-to-Satisfy Provisions of Part D3 do not apply to a farm shed.
- I3D5 Fixed platforms, walkways, stairways and ladders SAA fixed platform, stairway, ladder and any going and riser, landing, handrail or barrier may comply with AS 1657 in lieu of D3D14, D3D15, D3D17 to…
- I3D6 ThresholdsThe threshold of a doorway that serves an area not required to be accessible by D4D2 in a farm building need not comply with D3D16 where the door…
- I3D7 Swinging doorsA swinging door in a required exit or forming part of a required exit need not swing in the direction of egress if it serves a farm building.
- I3D8 Fire fighting equipment SAThe Deemed-to-Satisfy Provisions of Part E1 do not apply to a farm shed.
- I3D9 Fire hydrants and water supplies SAThis provision applies to a farm building — with a total floor area greater than 500 m2; and located where a fire brigade station is— not more than…
- I3D10 Fire hose reels SAA fire hose reel system need not be provided to serve a farm building where portable fire extinguishers are installed in accordance with I3D11.
- I3D11 Portable fire extinguishers SAA farm building not provided with a fire hose reel system in accordance with E1D3 must be provided with— one portable fire extinguisher rated at not…
- I3D12 Emergency lighting requirements SAAn emergency lighting system need not be installed in a farm building — with no artificial lighting as permitted by I3D18; or with artificial…
- I3D13 Exit signs SAAn exit serving a farm shed need not be provided with an exit sign where the exit is a permanent opening not less than 2 m wide.
- I3D14 Direction signs SAIn a farm building or a farm shed, if an exit is not readily apparent to persons occupying or visiting the building, exit signs complying with I3D15…
- I3D15 Design and operation of exit signs SAIn a farm building, each required exit sign provided under E4D5 and I3D14 need not comply with E4D8 if— the use of illuminated exit signs may…
- I3D16 Sanitary facilities SAF4D4 does not apply to a farm shed.
- I3D17 Height of rooms and other spaces SAF5D2 does not apply to a farm shed which has ceiling heights not less than— in a room, corridor, passageway or the like — 2.1 m; and in a room or…
- I3D18 Artificial lighting SAAn artificial lighting system need not be provided in a farm building where— occupants are provided with visibility sufficient for safe movement…