Queensland variation · NCC 2025 Volume One
QLD G5D2 Application of Part
QLD Part G5 Construction in bushfire prone areas · varies G5D2 Application of Part
Delete clause G5D2 and insert QLD G5D2 as follows:
(1) The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to—
a Class 2 or 3 building; or
a Class 9a health-care building; or
a Class 9b—
an early childhood centre; or
a primary or secondary school; or
a Class 9c residential care building; or
a Class 10a building or deck associated with a building of a type listed in (a) to (d).
(2) The Deemed-to-Satisfy Provisions of this Part do not apply when the classified vegetation is Group F rainforest (excluding wet sclerophyll forest types), mangrove communities and grasslands under 300 mm high.
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One QLD G5D2.