S43C7 Access pathways
Specification 43 Bushfire protection for certain Class 9 buildings
(1) Access pathways that lead to a road or open space must—
be readily identifiable; and
have an even surface; and
have a minimum clear width of not less than 1 m.
(2) If the access pathway is an accessway that is required to comply with Part D4, the requirements of Part D4 override (1) to the extent of any inconsistency.
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One S43C7.