Delete subclause D4D2(4) and insert SA D4D2(4) as follows:
(4) For a Class 2 building, access requirements are as follows:
Common areas:
From a pedestrian entrance required to be accessible to at least one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.
To and within not less than one of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, individual shop, eating area, or the like.
Where a ramp complying with AS 1428.1 or a passenger lift is installed—
to the entrance doorway of each sole-occupancy unit; and
to and within rooms or spaces for use in common by the residents.
The requirements of (iii) only apply where the space referred to in (iii)(A) or (iii)(B) is located on the levels served by the lift or ramp.
In developments consisting of 20 or more residential sole-occupancy units — to and within one residential sole-occupancy unit or 5% of the total number of residential sole-occupancy units provided, whichever is the greater, must be accessible.
Changed since NCC 2022 (minor wording). See NCC 2022 Volume One SA D4D2, or show what changed.
Delete subclause D4D2(4) and insert SA D4D2(4) as follows: (4) … a pedestrian entrance required to be accessible to at least 1 one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level. To and within not less than 1 one of each type of room or space for use in … sole-occupancy units provided, whichever is the greater, must be accessible.