Table · NCC 2025 Volume One
Table F4D4f Sanitary facilities in Class 9b buildings – schools
Part F4 Sanitary and other facilities
| User group | Facility type | Design occupancy | Number |
|---|---|---|---|
| Male employees | Closet pans | 1 - 20 | 1 |
| >20 | Add 1 per 20 | ||
| Urinals | 1 - 10 | 0 | |
| 11 - 20 | 1 | ||
| 21 - 45 | 2 | ||
| >45 | Add 1 per 30 | ||
| Washbasins | 1 -30 | 1 | |
| >30 | Add 1 per 30 | ||
| Female employees | Closet pans | 1 - 5 | 1 |
| >5 | Add 1 per 15 | ||
| Washbasins | 1 - 30 | 1 | |
| >30 | Add 1 per 30 | ||
| Male students | Closet pans | 1 - 25 | 1 |
| 26 - 75 | 2 | ||
| 76 - 150 | 3 | ||
| 151 - 200 | 4 | ||
| >200 | Add 1 per 100 | ||
| Urinals | 1 - 50 | 1 | |
| 51 - 100 | 2 | ||
| >100 | Add 1 per 100 | ||
| Washbasins | 1 - 10 | 1 | |
| 11 - 50 | 2 | ||
| 51 - 100 | 3 | ||
| >100 | Add 1 per 75 | ||
| Female students | Closet pans | 1 - 10 | 1 |
| 11 - 25 | 2 | ||
| 26 - 100 | Add 1 per 25 | ||
| >100 | Add 1 per 50 | ||
| Washbasins | 1 - 10 | 1 | |
| 11 - 50 | 2 | ||
| 51 - 100 | 3 | ||
| >100 | Add 1 per 75 |
Table for F4D4 Facilities in Class 3 to 9 buildings
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table F4D4f.