NCC 2025 Volume One
Part F4 Sanitary and other facilities
36 clauses · Open on NCC Online ↗
- F4O1 ObjectivesThe Objective of this Part is to— safeguard occupants from illness caused by infection; and safeguard occupants from loss of amenity arising from…
- F4F1 Sanitary facilitiesA building is to be provided with— suitable sanitary facilities and space and facilities for personal hygiene; and adequate means for the prevention…
- F4F2 Laundry facilitiesA building is to be provided with— space or facilities for laundering; and suitable means for the sanitary disposal of waste water. Applications…
- F4F3 Food preparation facilitiesA building is to be provided with— space and facilities for the preparation and cooking of food; and suitable means for the sanitary disposal of…
- F4F4 Removal of unconscious occupantA sanitary compartment is to have sufficient space or other means to permit an unconscious occupant to be removed from the compartment.
- F4P1 Personal hygiene facilitiesSuitable sanitary facilities for personal hygiene must be provided in a convenient location within or associated with a building, to the degree…
- F4P2 Laundry facilitiesLaundering facilities or space for laundering facilities and the means for the sanitary disposal of waste water must be provided in a convenient…
- F4P3 Kitchen facilitiesA facility must be provided which includes— a means for food rinsing, utensil washing and the sanitary disposal of associated waste water; and a…
- F4P4 Disposal of contaminated water from containersSuitable means must be provided in a building containing wards or bedrooms to facilitate the emptying of sewage or dirty water from containers.…
- F4P5 Construction of sanitary compartments to allow removal of unconscious peopleA sanitary compartment must be constructed with sufficient space or other means to permit an unconscious occupant to be removed from the compartment.
- F4P6 Microbial control for water systems NSWHot water, warm water and cooling water systems installed in a building must control the accumulation of harmful levels of micro-organisms.…
- F4V1 Sanitary facilitiesCompliance with F4P1, for the number of sanitary facilities, is verified when queuing modelling predicts that occupant waiting time for sanitary…
- F4D1 Deemed-to-Satisfy Provisions SA VICWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to F4P6 are satisfied by complying with— F4D2 to F4D12; and for public…
- F4D2 Facilities in residential buildings VICFor facilities in Class 2 buildings, the following applies: Within each sole-occupancy unit, provide— a kitchen sink and facilities for the…
- F4D3 Calculation of number of occupants and facilitiesThe number of persons accommodated must be calculated according to D2D18 if it cannot be more accurately determined by other means. (2) Unless the…
- Table F4D4a Sanitary facilities in Class 3, 5, 6 and 9 buildings other than schoolsUser group | Facility type | Design occupancy | Number Male employees | Closet pans | 1 - 20 | 1 >20 | Add 1 per 20 Urinals | 1 - 10 | 0 11 - 25 | 1…
- Table F4D4b Sanitary facilities in Class 7 and 8 buildingsUser group | Facility type | Design occupancy | Number Male employees | Closet pans | 1 - 20 | 1 >20 | Add 1 per 20 Urinals | 1 - 10 | 0 11 - 25 | 1…
- Table F4D4c Sanitary facilities in Class 6 buildings – department stores, shopping centresUser group | Facility type | Design occupancy | Number Male patrons | Closet pans | 1 - 1200 | 1 >1200 | Add 1 per 1200 Urinals | 1 - 600 | 1 >600 |…
- Table F4D4d Sanitary facilities in Class 6 buildings – restaurants, cafes, barsUser group | Facility type | Design occupancy | Number Male patrons | Closet pans | 1 - 100 | 1 101 - 300 | 2 >300 | Add 1 per 200 Urinals | 1 - 50…
- Table F4D4e Sanitary facilities in Class 9a health-care buildingsUser group | Facility type | Design occupancy | Number Male patients | Closet pans | 1 - 16 | 2 >16 | Add 1 per 8 Washbasins | 1 - 8 | 1 >8 | Add 1…
- Table F4D4f Sanitary facilities in Class 9b buildings – schoolsUser group | Facility type | Design occupancy | Number Male employees | Closet pans | 1 - 20 | 1 >20 | Add 1 per 20 Urinals | 1 - 10 | 0 11 - 20 | 1…
- Table F4D4g Sanitary facilities in Class 9b buildings – early childhood centresUser group | Facility type | Design occupancy | Number Children | Closet pans | 1 - 30 | 2 >30 | Add 1 per 15 Washbasins | 1 - 30 | 2 >30 | Add 1…
- Table F4D4h Sanitary facilities in Class 9b buildings – theatres and cinemas with multiple auditoria, art galleries and the likeUser group | Facility type | Design occupancy | Number Male participants | Closet pans | 1 - 20 | 1 >20 | Add 1 per 20 Urinals | 1 - 10 | 1 >10 |…
- Table F4D4i Sanitary facilities in Class 9b buildings – single auditorium theatres and cinemasUser group | Facility type | Design occupancy | Number Male patrons | Closet pans | 1 - 50 | 0 51 - 250 | 1 251 - 500 | 2 >500 | Add 1 per 500…
- Table F4D4j Sanitary facilities in Class 9b buildings – sports venues or the likeUser group | Facility type | Design occupancy | Number Male participants | Closet pans | 1 - 20 | 1 >20 | Add 1 per 20 Urinals | 1 - 10 | 1 >10 |…
- Table F4D4k Sanitary facilities in Class 9b buildings – churches, chapels or the likeUser group | Facility type | Design occupancy | Number Male patrons | Closet pans | 1 - 300 | 1 >300 | Add 1 per 500 Urinals | 1 - 200 | 1 >200 |…
- Table F4D4l Sanitary facilities in Class 9b buildings – public halls, function rooms or the likeUser group | Facility type | Design occupancy | Number Male patrons | Closet pans | 1 - 100 | 1 >100 | Add 1 per 200 Urinals | 1 - 50 | 1 51 - 100 |…
- F4D4 Facilities in Class 3 to 9 buildings NT TAS VICExcept where permitted by (3), (4), (7), (12), F4D5(a), F4D5(b) and F4D12(1), separate sanitary facilities for males and females must be provided…
- F4D5 Accessible sanitary facilitiesIn a building required to be accessible — accessible unisex sanitary compartments must be provided in accessible parts of the building in accordance…
- F4D6 Accessible unisex sanitary compartments SAWhere required by F4D5(a), the minimum number of accessible unisex sanitary compartments for each class of building is as follows: For a Class 1b…
- F4D7 Accessible unisex showers SAWhere required by F4D5(b), the minimum number of accessible unisex showers for each class of building is as follows: For a Class 1b building— not…
- F4D8 Construction of sanitary compartments VICOther than in an early childhood centre, sanitary compartments must have doors and partitions that separate adjacent compartments and extend— from…
- F4D9 Interpretation: urinals and washbasinsA urinal may be— an individual stall or wall-hung urinal; or each 600 mm length of a continuous urinal trough; or a closet pan used in place of a…
- F4D10 Microbial (legionella) control NSWHot water, warm water and cooling water systems in a building other than a system serving only a single sole-occupancy unit in a Class 2 or 3…
- F4D11 Waste managementIn a Class 9a health-care building, at least one slop-hopper or other device, other than a water closet pan or urinal, must be provided— on any…
- F4D12 Accessible adult change facilitiesOne unisex accessible adult change facility must be provided in an accessible part of a— Class 6 building that is a shopping centre having a design…