Table · NCC 2025 Volume One
Table J3D12a Constant for Solar Heat Gain (CSHGC) — climate zones 1 to 7
Part J3 Elemental provisions for a Class 4 part of a building
| % Ventilation opening area per m2 | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7 |
|---|---|---|---|---|---|---|---|
| 5% to <10% | 0.0191 | 0.0245 | 0.0547 | 0.0506 | 0.0674 | 0.1472 | 0.0930 |
| 10% to <15% | 0.0237 | 0.0532 | 0.0745 | 0.0946 | 0.1111 | 0.2969 | 0.2405 |
| 15% to <20% | 0.0294 | 0.0700 | 0.0861 | 0.1203 | 0.1367 | 0.3845 | 0.3267 |
| 20% to 90% | 0.0364 | 0.0819 | 0.0943 | 0.1385 | 0.1548 | 0.4466 | 0.3879 |
Table Notes
The ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.
No window can have a design ventilation opening greater than 90% because the window frame will always obstruct some area of the opening.
Interpolation is allowed for values between those shown.
Table for J3D12 External summer glazing of a Class 4 part of a building
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D12a.