Table · NCC 2025 Volume One

Table J3D12c Orientation sector summer exposure factor (Es) — climate zone 2

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D12c on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.651.161.591.200.731.301.771.23
0.050.541.011.431.060.611.181.621.10
0.100.500.941.350.990.581.101.501.00
0.200.420.811.200.880.510.981.320.87
0.400.350.620.950.700.400.781.100.67
0.600.300.480.780.570.330.640.880.50
0.800.260.410.650.470.290.540.770.43
1.000.230.330.560.400.240.470.620.36
1.200.210.300.460.350.220.400.540.31
1.400.190.260.420.320.210.350.480.27
1.600.170.250.360.290.190.310.410.24
1.800.150.220.310.250.170.300.370.22
2.000.150.210.290.240.160.260.360.21

Table for J3D12 External summer glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D12c.