Table · NCC 2025 Volume One

Table J3D12d Orientation sector summer exposure factor (Es) — climate zone 3

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D12d on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.801.261.411.380.891.331.291.20
0.050.671.141.311.260.771.211.201.07
0.100.631.031.241.190.731.141.130.99
0.200.540.881.091.050.621.001.010.87
0.400.460.680.870.830.510.830.800.67
0.600.400.520.730.680.420.660.670.52
0.800.340.420.580.550.360.580.570.42
1.000.290.350.500.470.320.490.500.35
1.200.270.310.420.400.280.430.410.31
1.400.240.270.350.360.270.370.390.27
1.600.240.240.330.320.220.360.330.25
1.800.210.230.300.280.220.320.310.23
2.000.210.220.250.280.200.280.260.20

Table for J3D12 External summer glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D12d.