Table · NCC 2025 Volume One
Table J3D14a Floor area adjustment factor for a Class 4 part of a building
Part J3 Elemental provisions for a Class 4 part of a building
| Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor |
|---|---|---|---|---|---|---|---|
| < 50 | 0.0123 | 160–169 | 0.0097 | 280–289 | 0.0087 | 400–409 | 0.0080 |
| 50–59 | 0.0119 | 170–179 | 0.0096 | 290–299 | 0.0086 | 410–419 | 0.0079 |
| 60–69 | 0.0116 | 180–189 | 0.0095 | 300–309 | 0.0085 | 420–429 | 0.0079 |
| 70–79 | 0.0113 | 190–199 | 0.0094 | 310–319 | 0.0085 | 430–439 | 0.0078 |
| 80–89 | 0.0111 | 200–209 | 0.0093 | 320–329 | 0.0084 | 440–449 | 0.0078 |
| 90–99 | 0.0108 | 210–219 | 0.0092 | 330–339 | 0.0083 | 450–459 | 0.0077 |
| 100–109 | 0.0106 | 220–229 | 0.0091 | 340–349 | 0.0083 | 460–469 | 0.0077 |
| 110–119 | 0.0105 | 230–239 | 0.0090 | 350–359 | 0.0082 | 470–479 | 0.0077 |
| 120–129 | 0.0103 | 240–249 | 0.0090 | 360–369 | 0.0082 | 480–489 | 0.0076 |
| 130–139 | 0.0101 | 250–259 | 0.0089 | 370–379 | 0.0081 | 490–499 | 0.0076 |
| 140–149 | 0.0100 | 260–269 | 0.0088 | 380–389 | 0.0081 | 500 | 0.0075 |
| 150–159 | 0.0099 | 270–279 | 0.0087 | 390–399 | 0.0080 | — | — |
Table Notes
The total floor area is measured within the inside face of the external walls of the sole-occupancy unit and includes any conditioned attached Class 10a building.
Where values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.
Table for J3D14 Net equivalent energy usage of a Class 4 part of a building
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D14a.