Table · NCC 2022 Volume One

Table J3D14a Floor area adjustment factor for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Open Table J3D14a on NCC Online ↗
Total floor area m2Floor area factorTotal floor area m2Floor area factorTotal floor area m2Floor area factorTotal floor area m2Floor area factor
< 500.0123160–1690.0097280–2890.0087400–4090.0080
50–590.0119170–1790.0096290–2990.0086410–4190.0079
60–690.0116180–1890.0095300–3090.0085420–4290.0079
70–790.0113190–1990.0094310–3190.0085430–4390.0078
80–890.0111200–2090.0093320–3290.0084440–4490.0078
90–990.0108210–2190.0092330–3390.0083450–4590.0077
100–1090.0106220–2290.0091340–3490.0083460–4690.0077
110–1190.0105230–2390.0090350–3590.0082470–4790.0077
120–1290.0103240–2490.0090360–3690.0082480–4890.0076
130–1390.0101250–2590.0089370–3790.0081490–4990.0076
140–1490.0100260–2690.0088380–3890.00815000.0075
150–1590.0099270–2790.0087390–3990.0080——

Table Notes

The total floor area is measured within the inside face of the external walls of the sole-occupancy unit and includes any conditioned attached Class 10a building.

Where values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.

Table for J3D14 Net equivalent energy usage of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table J3D14a.

Defined terms used