Table · NCC 2025 Volume One
Table J3D7v Direction of heat flow
Part J3 Elemental provisions for a Class 4 part of a building
| Climate zone | Direction of heat flow |
|---|---|
| 1 | Down |
| 2 – altitude less than 300 m | Down |
| 2 – altitude 300 m or more | Down and up |
| 3 | Down and up |
| 4 | Up |
| 5 | Up |
| 6 | Up |
| 7 | Up |
| 8 | Up |
Table for J3D7 Roofs and ceilings of a Class 4 part of a building
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D7v.