Tasmania variation · NCC 2025 Volume One

TAS I4D4 Pests and contaminants

TAS Part I4 Food premises

Open on NCC Online ↗

Delete clause I4D4 and insert TAS I4D4 as follows:

Premises where customers are served outside the premises through an opening, that has an appliance for the elimination of flies and mechanical ventilation adequate to exhaust air through the opening at a rate of not less than 5 litres per second for each square metre of opening, satisfies TAS I4P2(d).

Changed since NCC 2022. See NCC 2022 Volume One TAS I4D4, or show what changed.

Delete clause I4D4 and insert TAS I4D4 as follows: Premises where customers are served outside the premises through an … second for each square metre of opening, satisfies TAS I4P2(d).

Removed words are struck through; added words are highlighted. Comparison of the text only.