WA I4D6 Artificial lighting
WA Part I4 Public buildings
Delete clause I4D6 and insert WA I4D6 as follows:
(1) Artificial lighting must be provided along the external path of travel (including steps, landings, ramps or paths) to a road or open space associated with each exit from a WA public building.
(2) The artificial lighting system required by (1) must—
provide a minimum illuminance of 1 lux at ground level; and
be connected to circuits separate from those supplying lighting for foyers, entry porches, emergency escape passages or areas provided entry or egress to the WA public building; and
be connected over two circuits where two or more lights are required; and
have switches that are not able to be operated by members of the public.
Changed since NCC 2022. See NCC 2022 Volume One WA I4D6, or show what changed.
Delete clause I4D6 and insert WA I4D6 as follows: (1) Artificial lighting must be provided along the external path … not able to be operated by members of the public.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Other states and territories
- NSW Delete clause I4D6 and insert NSW I4D6 as follows: If a room or area is not separated from the remainder of a…
- SA Delete clause I4D6 and insert SA I4D6 as follows: (1) A bulk grain storage facility need not provide an on-site fire…
- TAS Delete clause I4D6 and insert TAS I4D6 as follows: Where offensive material or trade waste is stored, a separate area…