Housing Provisions clause · ABCB Housing Provisions 2022

10.2.14 Shower area requirements

Part 10.2 Wet area waterproofing

Open 10.2.14 on NCC Online ↗

Shower areas must be designed as either enclosed or unenclosed—

to include a floor waste with falls complying with 10.2.12; and

with a—

stepdown complying with 10.2.15; or

hob complying with 10.2.16; or

level threshold complying with 10.2.17.

Changed in NCC 2025. See ABCB Housing Provisions 2025 10.2.14, or show what changed.

(1) Shower areas must be designed as either enclosed or unenclosed — to include unenclosed. (2) Shower areas must incorporate a floor waste with falls complying with 10.2.12; and with a 10.2.12. (3) Enclosed shower areas must incorporate — stepdown complying with 10.2.15; or hob complying with 10.2.16; or level threshold complying with 10.2.17. 10.2.17; or preformed shower base complying with 10.2.19. (4) Unenclosed shower areas must be constructed in accordance with 10.2.15 or 10.2.18.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Clauses referred to

Defined terms used