Footings and slabs, including internal and edge beams, must be founded on soil with an allowable bearing pressure as follows:

Slab panels, load support panels and internal beams — natural soil with an allowable bearing pressure of not less than 50 kPa or controlled fill or rolled fill compacted in accordance with 4.2.4.

Edge beams connected to the slab — natural soil with an allowable bearing pressure of not less than 50 kPa or controlled fill compacted in accordance with 4.2.4(a)(iii) and extending past the perimeter of the building 1 m with a slope ratio not steeper than 2 horizontal to 1 vertical (see Figure 4.2.5).

Pad footings, strip footings and edge beams not connected to the slab, must be—

founded in natural soil with an allowable bearing pressure of not less than 100 kPa; or

for Class A and S sites they may be founded on controlled sand fill in accordance with 4.2.4(a).

Figure 4.2.5 Foundations for footings and slabs

Figure Notes

Compacted fill must be in accordance with 4.2.4.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 4.2.5.

Clauses referred to

Defined terms used