9.5.1 Smoke alarm requirements

Part 9.5 Smoke alarms and evacuation lighting · NCC 2019: NSW 3.7.5.2 and NSW 1.1.4, 3.7.5.2

Open 9.5.1 on NCC Online ↗
Varied in NSW. Check the variation for your state.

Smoke alarms must—

be located in—

a Class 1a building in accordance with 9.5.2 and 9.5.4; and

a Class 1b building in accordance with 9.5.3 and 9.5.4; and

comply with AS 3786, except that in a Class 10a private garage where the use of the area is likely to result in smoke alarms causing spurious signals, any other alarm deemed suitable in accordance with AS 1670.1 may be installed provided that smoke alarms complying with AS 3786 are installed elsewhere in the Class 1 building; and

be powered from the consumer mains source where a consumer mains source is supplied to the building; and

be interconnected where there is more than one alarm.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 9.5.1.