ABCB Housing Provisions 2022
Part 7.3 Roof tiles and shingles
8 clauses · Open on NCC Online ↗
- 7.3.1 ApplicationPart 7.3 applies subject to the limitations set out in H1D7. (2) Part 7.3 need not be complied with if H1D7(3)(a) or (b) are complied with.
- Table 7.3.2 Minimum fixing requirementsWind class | Tile fixing - edge of roof | Tile fixing - field of roof | Ridge, hip, barge and valley tiles including capping (see Figure 7.3.2d and…
- 7.3.2 Fixing of roof tiles and ancillariesRoof tiles and hip, ridge, barge and capping tiles must be fixed in accordance with Table 7.3.2 and Figure 7.3.2a, Figure 7.3.2b, Figure 7.3.2c,…
- 7.3.3 FlashingFlashing for roof tiles must comply with (2) to (7). (2) Wall and step flashings: For masonry or similar walls, flashing must— follow the roof line,…
- Table 7.3.4 Sarking requirements for tiled roofsRoof pitch | Maximum rafter/truss top chord length without sarking (mm) Note 1 <18° | N/A Note 2 ≥18° <20° | 4 500 ≥20° <22° | 5 500 ≥22° | 6 000…
- 7.3.4 SarkingSarking must— be provided in accordance with Table 7.3.4; and comply with AS 4200.1 and be installed with— each adjoining sheet or roll being—…
- 7.3.5 Anti-ponding device/boardAn anti-ponding device/board must be provided where sarking is installed on— roofs with a pitch less than 20°; and roofs with no eaves overhang,…
- 7.3.6 Water dischargeWhere an eaves gutter is provided in accordance with H2D6(1), tiles must overhang the fascia or tiling batten by not less than 35 mm (See Figure…