Table · ABCB Housing Provisions 2022

Table 13.2.3p Flat, skillion or cathedral roof – minimum R-Value for ceiling insulation: climate zone 6

Part 13.2 Building fabric

Open Table 13.2.3p on NCC Online ↗
Reflective insulation under-roof0.23 ≤ SA < 0.64SA = 0.640.64 < SA ≤ 0.96
Yes4.03.54.0
No4.04.04.0

Table Notes

SA = solar absorptance.

The R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.

The R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.

R-Values listed are for the labelled, declared R-Value of insulation.

Table for 13.2.3 Roofs and ceilings

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.3p.

Defined terms used