Table · ABCB Housing Provisions 2022

Table 13.2.3w Adjusted minimum R-Value of ceiling insulation required to compensate for loss of ceiling insulation area

Part 13.2 Building fabric

Open Table 13.2.3w on NCC Online ↗
Percentage of ceiling area uninsulatedMinimum R-Value of ceiling insulation required to satisfy 13.2.3(1) and (3)
1.01.52.02.53.03.54.04.55.05.5
0.5 to less than 1.0%1.01.62.22.83.44.04.75.46.26.9
1.0% to less than 1.5%1.11.72.32.93.64.45.26.17.0x
1.5% to less than 2.0%1.11.72.43.13.94.85.86.8xx
2.0% to less than 2.5%1.11.82.53.34.25.36.5xxx
2.5% to less than 3.0%1.21.92.63.64.65.9xxxx
3.0% to less than 4.0%1.22.03.04.25.7xxxxx
4.0% to less than 5.0%1.32.23.45.0xxxxxx

Table Notes

Interpolation is allowed for values between those shown.

X = not permitted.

Table for 13.2.3 Roofs and ceilings

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.3w.

Clauses referred to

Defined terms used