Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3

Part 13.3 External glazing

Open Table 13.3.2e on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.921.290.970.820.751.071.241.69
0.051.901.240.900.720.660.941.181.65
0.101.761.180.860.690.630.911.131.56
0.201.571.050.770.620.600.811.011.41
0.401.250.860.660.510.540.680.871.17
0.600.940.660.530.460.510.590.700.94
0.800.630.530.470.410.450.550.600.76
1.000.420.450.390.360.420.520.530.61
1.200.290.350.340.330.420.460.440.52
1.400.230.310.280.310.390.420.390.44
1.600.170.270.260.280.360.390.380.37
1.800.150.190.210.280.360.360.310.34
2.000.130.190.200.260.360.360.290.29

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2e.