Table · ABCB Housing Provisions 2022

Table 13.3.2i Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)

Part 13.3 External glazing

Open Table 13.3.2i on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.611.551.000.430.330.431.111.66
0.051.561.490.910.360.280.361.011.59
0.101.561.430.860.340.270.350.981.54
0.201.301.270.770.310.240.310.871.39
0.401.191.050.640.260.210.260.721.16
0.600.970.870.520.230.190.230.610.95
0.800.780.710.460.210.170.210.550.77
1.000.640.550.360.190.160.190.470.66
1.200.430.480.330.180.150.180.380.53
1.400.320.360.270.170.140.170.360.45
1.600.220.320.250.150.130.140.300.38
1.800.180.260.210.140.130.140.260.34
2.000.140.200.200.130.130.130.250.25

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2i.