Table 13.3.3b Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 1

Part 13.3 External glazing

Open Table 13.3.3b on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.351.641.691.621.131.651.721.66
0.051.141.451.561.470.981.521.601.46
0.101.071.331.451.400.881.421.501.35
0.200.961.151.321.230.721.221.301.17
0.400.780.881.030.900.550.981.080.92
0.600.650.720.860.770.440.780.860.74
0.800.570.610.690.610.390.680.750.62
1.000.490.510.590.540.330.560.620.55
1.200.470.450.480.430.290.510.550.51
1.400.440.410.420.390.290.420.480.43
1.600.390.350.370.340.230.380.440.41
1.800.340.350.350.290.220.360.390.35
2.000.310.330.300.270.210.310.360.33

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3b.