Table · ABCB Housing Provisions 2022

Table 13.3.3o Orientation sector summer exposure factor (ES) — suspended floor: climate zone 6

Part 13.3 External glazing

Open Table 13.3.3o on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.881.051.040.570.240.962.001.54
0.050.750.950.950.510.210.881.861.40
0.100.680.880.890.480.200.831.791.29
0.200.550.750.790.420.180.751.601.13
0.400.380.570.640.350.140.611.290.86
0.600.320.420.550.290.120.531.090.63
0.800.270.340.450.250.100.460.940.50
1.000.230.280.380.210.090.380.800.45
1.200.210.230.330.190.090.360.690.36
1.400.190.210.290.170.080.310.600.32
1.600.170.190.250.160.070.280.540.26
1.800.160.180.230.140.070.260.490.25
2.000.150.170.220.140.070.240.440.21

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3o.