Table · ABCB Housing Provisions 2022

Table 13.3.3n Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 6

Part 13.3 External glazing

Open Table 13.3.3n on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.011.191.150.780.491.101.821.55
0.050.851.071.050.700.421.011.691.41
0.100.780.990.990.670.390.961.631.30
0.200.620.850.880.590.350.861.461.14
0.400.430.640.710.490.290.701.170.86
0.600.360.470.610.410.250.610.990.64
0.800.310.390.500.340.210.530.860.50
1.000.260.320.420.290.180.440.730.45
1.200.240.260.370.260.180.410.620.36
1.400.220.240.320.230.150.360.550.33
1.600.190.210.280.220.140.330.490.26
1.800.180.200.260.200.140.290.440.25
2.000.170.190.240.190.140.270.400.21

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3n.