Table · ABCB Housing Provisions 2022

Table 13.3.3w Summer solar heat gain factors: climate zone 5 (concrete or masonry wall)

Part 13.3 External glazing

Open Table 13.3.3w on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RS) for a bedroom and a room which is not a conditioned space0.500.35
Level factor (LS) for all other floor levels1.401.30
Frame factor (FS) for frames with a solar absorptance of ≤ 0.400.890.90
Frame factor (FS) for frames with a solar absorptance of > 0.40 to < 0.681.000.95
Frame factor (FS) for frames with a solar absorptance of ≥ 681.181.00
Floor factor (for tiled or vinyl covered floor) (HS)0.60Not applicable

Table Notes

This Table only applies to dwellings with both high mass external and internal walls, for example masonry cavity external and internal walls.

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3w.

Defined terms used