Table · ABCB Housing Provisions 2022

Table 13.3.3v Summer solar heat gain factors: climate zone 5 (lightweight or masonry veneer wall)

Part 13.3 External glazing

Open Table 13.3.3v on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RS) for a bedroom and a room which is not a conditioned space0.450.52
Level factor (LS) for all other floor levels1.201.45
Frame factor (FS) for frames with a solar absorptance of ≤ 0.400.880.73
Frame factor (FS) for frames with a solar absorptance of > 0.40 to < 0.681.000.78
Frame factor (FS) for frames with a solar absorptance of ≥ 0.681.201.00
Floor factor (for tiled or vinyl covered floor) (HS)0.65Not applicable

Table Notes

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3v.