Table · ABCB Housing Provisions 2022

Table 7.4.4a Overflow volume for continuous measure (L/s/m)

Part 7.4 Gutters and downpipes

Open Table 7.4.4a on NCC Online ↗
Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d)Ridge to gutter length — 2 mRidge to gutter length — 4 mRidge to gutter length — 6 mRidge to gutter length — 8 mRidge to gutter length — 10 mRidge to gutter length — 12 mRidge to gutter length — 14 mRidge to gutter length — 16 m
150 mm/h0.08 L/s/m0.17 L/s/m0.25 L/s/m0.33 L/s/m0.42 L/s/m0.50 L/s/m0.58 L/s/m0.67 L/s/m
175 mm/h0.10 L/s/m0.19 L/s/m0.29 L/s/m0.39 L/s/m0.49 L/s/m0.58 L/s/m0.68 L/s/m0.78 L/s/m
200 mm/h0.11 L/s/m0.22 L/s/m0.33 L/s/m0.44 L/s/m0.56 L/s/m0.67 L/s/m0.78 L/s/m0.89 L/s/m
225 mm/h0.13 L/s/m0.25 L/s/m0.38 L/s/m0.50 L/s/m0.63 L/s/m0.75 L/s/m0.88 L/s/m1.0 L/s/m
250 mm/h0.14 L/s/m0.28 L/s/m0.42 L/s/m0.56 L/s/m0.69 L/s/m0.83 L/s/m0.97 L/s/m1.1 L/s/m
275 mm/h0.15 L/s/m0.31 L/s/m0.46 L/s/m0.61 L/s/m0.76 L/s/m0.92 L/s/m1.1 L/s/m1.2 L/s/m
300 mm/h0.17 L/s/m0.33 L/s/m0.50 L/s/m0.67 L/s/m0.83 L/s/m1.0 L/s/m1.2 L/s/m1.3 L/s/m
325 mm/h0.18 L/s/m0.36 L/s/m0.54 L/s/m0.72 L/s/m0.90 L/s/m1.1 L/s/m1.3 L/s/m1.4 L/s/m
350 mm/h0.19 L/s/m0.39 L/s/m0.58 L/s/m0.78 L/s/m0.97 L/s/m1.2 L/s/m1.4 L/s/m1.6 L/s/m
375 mm/h0.21 L/s/m0.42 L/s/m0.63 L/s/m0.83 L/s/m1.0 L/s/m1.3 L/s/m1.5 L/s/m1.7 L/s/m
400 mm/h0.22 L/s/m0.44 L/s/m0.67 L/s/m0.89 L/s/m1.1 L/s/m1.3 L/s/m1.6 L/s/m1.8 L/s/m

Table for 7.4.4 Installation of gutters

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 7.4.4a.