Table · ABCB Housing Provisions 2022
Table 7.4.4b Overflow volume for dedicated measure (L/s)
Part 7.4 Gutters and downpipes
| Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d) | Roof catchment area — 30 m2 | Roof catchment area — 40 m2 | Roof catchment area — 50 m2 | Roof catchment area — 60 m2 | Roof catchment area — 70 m2 |
|---|---|---|---|---|---|
| 150 mm/h | 1.3 L/s | 1.7 L/s | 2.1 L/s | 2.5 L/s | 2.9 L/s |
| 175 mm/h | 1.5 L/s | 1.9 L/s | 2.4 L/s | 2.9 L/s | 3.4 L/s |
| 200 mm/h | 1.7 L/s | 2.2 L/s | 2.8 L/s | 3.3 L/s | 3.9 L/s |
| 225 mm/h | 1.9 L/s | 2.5 L/s | 3.1 L/s | 3.8 L/s | 4.4 L/s |
| 250 mm/h | 2.1 L/s | 2.8 L/s | 3.5 L/s | 4.2 L/s | 4.9 L/s |
| 275 mm/h | 2.3 L/s | 3.1 L/s | 3.8 L/s | 4.6 L/s | 5.3 L/s |
| 300 mm/h | 2.5 L/s | 3.3 L/s | 4.2 L/s | 5.0 L/s | 5.8 L/s |
| 325 mm/h | 2.7 L/s | 3.6 L/s | 4.5 L/s | 5.4 L/s | 6.3 L/s |
| 350 mm/h | 2.9 L/s | 3.9 L/s | 4.9 L/s | 5.8 L/s | 6.8 L/s |
| 365 mm/h | 3.1 L/s | 4.2 L/s | 5.2 L/s | 6.3 L/s | 7.3 L/s |
| 400 mm/h | 3.3 L/s | 4.4 L/s | 5.6 L/s | 6.7 L/s | 7.8 L/s |
Table for 7.4.4 Installation of gutters
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 7.4.4b.