- 7.4.1 ApplicationPart 7.4 applies subject to H2D6(2) and the limitations set out in H2D6(3). (2) Part 7.4 need not be complied with if H2D6(1)(a) is complied with.
- 7.4.2 MaterialsGutters, downpipes and flashings must— be manufactured in accordance with AS/NZS 2179.1 for metal components; and be manufactured in accordance with…
- Table 7.4.3a Size of gutter required to drain roof catchment area into one (1) downpipe for various rainfall intensities and roof catchment areas (A, B, C, D, E and F defined in Table 7.4.3b)Design rainfall intensity (mm/h) (as per Table 7.4.3d) | Roof catchment area per downpipe — 30 m2 | Roof catchment area per downpipe — 40 m2 | Roof…
- Table 7.4.3b Gutter sizes for various rainfall intensitiesGutter type | Gutter description | Minimum cross-sectional area (mm2) A | Medium rectangular gutter | 6500 B | Large rectangular gutter | 7900 C |…
- Table 7.4.3c Downpipe selection for gutter types (A, B, C, D, E and F defined in Table 7.4.3b)Downpipe section | Gutter type A | Gutter type B | Gutter type C | Gutter type D | Gutter type E 75 mm dia. | Yes | Yes | Yes | Yes | No 100 mm x 50…
- Table 7.4.3d 5 minute duration rainfall intensitiesState | Locality | Annual exceedance probability, 5% (mm/h) | Annual exceedance probability, 1% (mm/h) ACT | Canberra | 143 | 192 ACT | Gungahlin |…
- 7.4.3 Selection of gutteringThe size of guttering must— for eaves gutters, be in accordance with Table 7.4.3a, Table 7.4.3b and Table 7.4.3c; and be suitable to remove…
- Table 7.4.4a Overflow volume for continuous measure (L/s/m)Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d) | Ridge to gutter length — 2 m | Ridge to gutter length — 4 m | Ridge to…
- Table 7.4.4b Overflow volume for dedicated measure (L/s)Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d) | Roof catchment area — 30 m2 | Roof catchment area — 40 m2 | Roof catchment…
- Table 7.4.4c Valley gutters — DimensionsDesign rainfall intensity mm/h | Sheet width (minimum, mm) | Effective depth (he), (minimum, mm) | Effective width (we), (minimum, mm) ≤200 | 355 |…
- 7.4.4 Installation of guttersEaves gutters must be— installed with a fall of not less than 1:500; and supported by brackets securely fixed at stop ends, corners and at not more…
- 7.4.5 Downpipes – size and installationDownpipes must— not serve more than 12 m of gutter length for each downpipe; and be located as close as possible to valley gutters; and be selected…
- 7.4.6 Acceptable continuous overflow measureFor a front face slotted gutter with— a minimum slot opening area of 1200 mm2 per metre of gutter; and the lower edge of the slots installed a…
- 7.4.7 Acceptable dedicated overflow measure per downpipeFor an end-stop weir with— a minimum clear width of 100 mm; and the weir edge installed a minimum 25 mm below the top of the fascia, the acceptable…