Performance Requirement · NCC 2022 Volume One

B1P2 Structural resistance

Part B1 Structural provisions · NCC 2019: BP1.2

Open B1P2 on NCC Online ↗

The structural resistance of materials and forms of construction must be determined using five percentile characteristic material properties with appropriate allowance for—

known construction activities; and

type of material; and

characteristics of the site; and

the degree of accuracy inherent in the methods used to assess the structural behaviour; and

action effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects.

Changed in NCC 2025. See NCC 2025 Volume One B1P2, or show what changed.

The structural resistance Glass installations that are at risk of materials being subjected to human impact must have glazing that — if broken on impact, will break in a way that is not likely to cause injury to people; and forms resists a reasonably foreseeable human impact without breaking; and is protected or marked in a way that will reduce the likelihood of construction must be determined using five percentile characteristic material properties with appropriate allowance for — known construction activities; and type of material; and characteristics of the site; and the degree of accuracy inherent in the methods used to assess the structural behaviour; and action effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects. human impact.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used