- B1O1 ObjectiveThe Objective of this Part is to— safeguard people from injury caused by structural failure; and safeguard people from loss of amenity caused by…
- B1F1 StructureA building or structure is to withstand the combination of loads and other actions to which it may be reasonably subjected.
- B1F2 GlazingGlazing is to be installed in a building to avoid undue risk of injury to people. (2) Glazing in a building should not cause injury to people due to…
- B1P1 Structural reliabilityBy resisting the actions to which it may reasonably be expected to be subjected, a building or structure, during construction and use, with…
- B1P2 Structural resistanceThe structural resistance of materials and forms of construction must be determined using five percentile characteristic material properties with…
- B1P3 Glass installations at risk of human impactGlass installations that are at risk of being subjected to human impact must have glazing that— if broken on impact, will break in a way that is not…
- B1P4 Buildings in flood areas QLD SAA building in a flood hazard area, must be designed and constructed, to the degree necessary, to resist flotation, collapse or significant permanent…
- Table B1V1a Annual action modelsDesign action | Ratio of mean action to nominal | Coefficient of variation of the action Permanent action | Imposed action | Wind action…
- Table B1V1b Annual target reliability indicesType of action | Target reliability index β Permanent action | 4.3 Imposed action | 4.0 Wind, snow and earthquake action | 3.7 Table Notes Table…
- B1V1 Structural reliabilityThis Verification Method is applicable to components with a resistance coefficient of variation of at least 10% and not more than 40%. (2) Where a…
- B1V2 Structural robustnessCompliance with B1P1(1)(c) is verified for structural robustness if (2) and (3) are complied with. (2) The structure is assessed such that the…
- B1D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements B1P1 to B1P4 are satisfied by complying with B1D2 to B1D6. (2) Where a…
- B1D2 Resistance to actionsThe resistance of a building or structure must be greater than the most critical action effect resulting from different combinations of actions,…
- Table B1D3a Importance Levels of buildings and structuresImportance level | Building Types 1 | Buildings or structures presenting a low degree of hazard to life and other property in the case of failure. 2…
- Table B1D3b Design events for safetyImportance level | Annual probability of exceedance for non-cyclonic wind | Annual probability of exceedance for cyclonic wind | Annual probability…
- B1D3 Determination of individual actions WAThe magnitude of individual actions must be determined in accordance with the following: Permanent actions: the design or known dimensions of the…
- Table B1D4 Material and minimum thickness of glazing and polycarbonate sheetApplication | Lift shaft vision panels more than 65 000 mm2, door panels, and lift shafts | Lift shaft vision panels less than or equal to 65 000…
- B1D4 Determination of structural resistance of materials and forms of construction NT QLD WAThe structural resistance of materials and forms of construction must be determined in accordance with the following, as appropriate: Masonry…
- B1D5 Structural softwareStructural software used in computer aided design of a building or structure, that uses design criteria based on the Deemed-to-Satisfy Provisions of…
- B1D6 Construction of buildings in flood hazard areas QLD SA VICA building in a flood hazard area must comply with the ABCB Standard for Construction of Buildings in Flood Hazard Areas. (2) The requirements of…