Performance Requirement · NCC 2022 Volume One

B1P4 Buildings in flood areas

Part B1 Structural provisions · NCC 2019: BP1.4

Open B1P4 on NCC Online ↗
Varied in QLD, SA. Check the variation for your state.

(1) A building in a flood hazard area, must be designed and constructed, to the degree necessary, to resist flotation, collapse or significant permanent movement resulting from the action of hydrostatic, hydrodynamic, erosion and scour, wind and other actions during the defined flood event.

(2) The actions and requirements to be considered to satisfy (1) include but are not limited to—

flood actions; and

elevation requirements; and

foundation and footing requirements; and

requirements for enclosures below the flood hazard level; and

requirements for structural connections; and

material requirements; and

requirements for utilities; and

requirements for occupant egress.

Applications

B1P4 only applies to—

a Class 2 or 3 building or a Class 4 part of a building; and

a Class 9a health-care building; and

a Class 9c building.

Not in NCC 2025. No B1P4 in NCC 2025 Volume One.

State and territory variations all clauses side by side →