Table B1V1a Annual action models
| Design action | Ratio of mean action to nominal | Coefficient of variation of the action |
|---|
Permanent action |
Imposed action |
Wind action (non-cyclonic) |
Wind action (cyclonic) |
Snow action |
Earthquake action |
Table for B1V1 Structural reliability
Changed in NCC 2025. See NCC 2025 Volume One Table B1V1a, or show what changed.
Design action | Ratio of mean action to nominal | Coefficient of variation of the action Permanent action | Imposed 1.05 | 0.10 Annual maximum imposed action | Wind action (non-cyclonic) 0.35 | Wind action (cyclonic) | Snow 0.45 Arbitrary-point-in-time imposed action | 0.25 | 0.78 Wind (non-cyclonic regions, Importance Level 1) | 0.37 | 0.47 Wind (non-cyclonic regions, Importance Level 2) | 0.31 | 0.47 Wind (non-cyclonic regions, Importance Level 3) | 0.29 | 0.47 Wind (non-cyclonic regions, Importance Level 4) | 0.27 | 0.47 Wind (cyclonic regions, Importance Level 1) | 0.19 | 0.76 Wind (cyclonic regions, Importance Level 2) | 0.16 | 0.76 Wind (cyclonic regions, Importance Level 3) | 0.14 | 0.76 Wind (cyclonic regions, Importance Level 4) | 0.13 | 0.76 Earthquake action (Importance Level 1) | 0.28 | 0.90 Earthquake (Importance Level 2) | 0.15 | 0.90 Earthquake (Importance Level 3) | 0.12 | 0.90 Earthquake (Importance Level 4) | 0.084 | 0.90 Snow | 0.29 | 0.57 Table Notes Actions not listed must be considered and derived on a case-by-case basis. Nominal loads are based on AS/NZS 1170 series of standards.
Removed words are struck through; added words are highlighted. Comparison of the text only.