D4D7 Signage
Part D4 Access for people with a disability · NCC 2019: D3.6
(1) In a building required to be accessible—
braille and tactile signage complying with Specification 15 must—
incorporate the international symbol of access or deafness, as appropriate, in accordance with AS 1428.1 and identify each—
sanitary facility, except a sanitary facility associated with a bedroom in a Class 1b building or a sole-occupancy unit in a Class 3 or Class 9c building; and
space with a hearing augmentation system; and
identify each door required by E4D5 to be provided with an exit sign and state—
“Exit”; and
“Level”; and
the floor level number or floor level descriptor, or a combination of the two.
signage including the international symbol for deafness in accordance with AS 1428.1 must be provided within a room containing a hearing augmentation system identifying—
the type of hearing augmentation; and
the area covered within the room; and
if receivers are being used and where the receivers can be obtained; and
signage in accordance with AS 1428.1 must be provided for accessible unisex sanitary facilities to identify if the facility is suitable for left or right handed use; and
signage to identify an ambulant accessible sanitary facility in accordance with AS 1428.1 must be located on the door of the facility; and
where a pedestrian entrance is not accessible, directional signage incorporating the international symbol of access, in accordance with AS 1428.1, must be provided to direct a person to the location of the nearest accessible pedestrian entrance; and
where a bank of sanitary facilities is not provided with an accessible unisex sanitary facility, directional signage incorporating the international symbol of access in accordance with AS 1428.1 must be placed at the location of the sanitary facilities that are not accessible, to direct a person to the location of the nearest accessible unisex sanitary facility.
(2) In a building that is subject to F4D12 and is required to be accessible, directional signage complying with Specification 15 to direct a person to the location of the nearest accessible adult change facility within that building must be provided at the location of each—
bank of sanitary facilities; and
accessible unisex sanitary facility, other than one that incorporates an accessible adult change facility.