Deemed-to-Satisfy Provision · NCC 2022 Volume One
E3D10 Residential care buildings
Part E3 Lift installations · NCC 2019: E3.8
(1) Where residents in a Class 9c residential care building are on levels which do not have direct access to a road or open space, the building must be provided with either—
at least one lift to accommodate a stretcher in accordance with E3D3(2); or
a ramp in accordance with AS 1428.1.
(2) The lift or ramp required by (1) must discharge at a level providing direct access to a road or open space.
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One E3D10.
Can't meet E3D10? A Performance Solution must meet the Performance Requirements it satisfies: E3P1, E3P2, E3P3, E3P4. Start a Performance Solution →